(9)* In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required for exits...
Search Results "Private Building"
-
4.1.3(9)*
-
1150A.1 General
SINGLE BUILDING WITH ONE COMMON (LOBBY) ENTRANCE The following may only be used for determining required access to covered multifamily dwelling units, in a single building with one common...
-
1150A.1 General
SINGLE BUILDING WITH ONE COMMON (LOBBY) ENTRANCE The following may only be used for determining required access to covered multifamily dwelling units, in a single building with one common...
- Alertus Voice Public Address System Interface
-
11B-207 Accessible means of egress
ETA Editor's Note From DSA's "Summary of 2022 California Building Code Changes for Accessibility in the Triennial Code Cycle": "Code amendment relocates Exceptions 1 and 2 (relating...
-
11B-221.2 Wheelchair spaces
The building code applies only to buildings and fixed elements attached to buildings or facilities....
-
Section 36.206 Retaliation or Coercion (Preamble, Section-by-Section Analysis)
Paragraph (a) of § 36.206 provides that no private entity or public entity shall discriminate against any individual because that individual has exercised his or her right to oppose any...
-
Subpart D—Preschool, Elementary, and Secondary Education
Although the subpart applies, in general, to both public and private education programs and activities that are federally assisted, §§104.32 and 104.33 apply only to public programs and...
-
Education's Intent To Revise its Section 504 Regulations To Adopt the 2010 Title II ADA Standards
Exception (1) to Section 206.2.3 exempts from this requirement certain private facilities that are less than three stories or that have less than 3000 square feet per story....
-
Occupant Load
The number of persons for which the means of egress of a building or portion of a building is designed....
-
106.5.39 Occupant Load
The number of persons for which the means of egress of a building or portion of a building is designed....
-
Slope: ADA Standard Section 405.2
Section 405.2 covers the current ADA Standards for slope requirements on ramps.
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-809.5.2 Residential dwelling unit smoke detection system and carbon monoxide detection system
ETA Editor's Note The lengthy California Building Code Chapter 9, Section 907.2.11 referenced above is not adopted by Division of the State Architect - Access Compliance (DSA-AC), and...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-809.5.2 Residential dwelling unit smoke detection system and carbon monoxide detection system
ETA Editor's Note The lengthy California Building Code Chapter 9, Section 907.2.11 referenced above is not adopted by Division of the State Architect - Access Compliance (DSA-AC), and...
-
11B-504.8 Floor identification
Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings...
-
11B-504.8 Floor identification
Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings...
-
Industry Standards
construction—Tolerances for building—Part 1: Basic principles for evaluation and specification ISO 3443-2 Building construction—Tolerances for building—Part 2: Statistical...
-
§100.201 Common use areas
Common use areas means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof....
-
R202.3.3 Reduction in Access Prohibited
An alteration shall not decrease or have the effect of decreasing the accessibility of a facility or an accessible connection to an adjacent building or site below the requirements for new...
-
INTERNATIONAL SYMBOL OF ACCESSIBILITY
[DSA-AC] The symbol adopted by Rehabilitation International’s 11th World Congress for the purpose of indicating that buildings and facilities are accessible to persons with disabilities....
-
INTERNATIONAL SYMBOL OF ACCESSIBILITY
[DSA-AC] The symbol adopted by Rehabilitation International’s 11th World Congress for the purpose of indicating that buildings and facilities are accessible to persons with disabilities....
-
F202.6 Leases
including new leases for buildings or facilities previously occupied by the Federal government, shall comply with F202.6....