EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum....
Search Results "Exception"
Commonly Searched Documents
-
309.4 Operation
-
504.4 Tread Surface
EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted....
-
309.4 Operation
EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum....
-
401.1 Scope
EXCEPTION: Hardware that is assistive technology shall not be required to conform to the requirements of this chapter....
-
B. Recruitment
may not limit their recruitment for employees to schools, communities, or companies disproportionately composed of persons of a particular race, color, national origin, sex, or handicap except...
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (13 mm) diameter except as allowed in 407.4.3, 409.4.3, 410.4, 810.5.3 and 810.10....
-
12183(a)(1)
) a failure to design and construct facilities for first occupancy later than 30 months after July 26, 1990, that are readily accessible to and usable by individuals with disabilities, except...
-
§ 36.105(d)(1)(ix)
(ix) The six-month “transitory” part of the “transitory and minor” exception in paragraph (f)(2) of this section does not apply to the “actual disability” or “record of” prongs of the definition...
-
211.2 Minimum Number
EXCEPTION: Where a single drinking fountain complies with 602.1 through 602.6 and 602.7, it shall be permitted to be substituted for two separate drinking fountains....
-
228.1 General
EXCEPTION: Drive-up only depositories shall not be required to comply with 309. Advisory 228.1 General....
-
§ 36.304(d)(1)
(1) Except as provided in paragraph (d)(3) of this section, measures taken to comply with the barrier removal requirements of this section shall comply with the applicable requirements for...
-
11B-406.5.1 Location
Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
-
11B-213.1 General
Where toilet facilities and bathing facilities are provided in facilities permitted by Section 11B-206.2.3 Exception 1 not to connect stories by an accessible route, toilet facilities and...
-
7.4.9 Trail Facilities
Exception. ...
-
309.4 Operation
EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum....
-
R103.1 Conventional Industry Tolerances
Dimensions are subject to conventional industry tolerances except where dimensions are stated as a range. Advisory R103.1 Conventional Industry Tolerances....
-
10.3.1(17)
EXCEPTION: Elevator cars with a clear floor area in which a 60 inch diameter circle can be inscribed may be substituted for the minimum car dimensions of 4.10, Fig. 22....
-
309.4 Operation
EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum. ...
-
4.1.3(2) ENTRANCES
EXCEPTION: In projects consisting of one-to-four family dwellings where accessible entrances would be extraordinarily costly due to site conditions or local code restrictions, accessible...
-
4.27.3* HEIGHT
Except where the use of special equipment dictates otherwise, electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
2.6 Passing Spaces
Exception. Where a vehicular way serves as the ORAR, the integrated ORAR shall not be required to comply with 2.6....