Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
Search Results "Elevator Car Door"
-
Size: ADA Standard Section 1008.3.2.1
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9.
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
Size: ADA Standard Section 1008.3.1.1
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
- SafeZone: Norton SafeZone Overview
-
Are public accommodations required to retrofit existing buildings by adding elevators?
Are public accommodations required to retrofit existing buildings by adding elevators?...
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
11B-407.2.2.3 Audible signals
Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel....
-
Handles, Pulls, and Knobs
Knobs that require a full hand grip and turning, including round door knobs and shower controls, do not comply because they require twisting of the wrist....
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
- How to Assess your Business for Accessibility
-
Opening Doors From a Wheelchair Video
Requires the Registered User plan or above. Login!
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
T502.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (810 mm) minimum.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
Scoping [4.1.3(7)]
Scoping [4.1.3(7)] Doors required to be accessible include: at least one door at each accessible entrance at least one door at each accessible space within a building...
-
Required Compliance [ยง206.6]
Only passenger elevators as classified by the referenced elevator safety code (ASME A17.1) can be used to meet the ADA Standards....