Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
Search Results "Clear"
Commonly Searched Documents
-
405.7.4 Change in Direction
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADAS] 904.4.2 Forward Approach. ...
-
406.6 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
4.7.10 DIAGONAL CURB RAMPS
The bottom of diagonal curb ramps shall have 48 in (1220 mm) minimum clear space as shown in Fig. 15(c) and (d)....
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADAS] 904.4.2 Forward Approach....
-
Video remote interpreting (VRI) services. (Section-by-Section Analysis)
NPRM, the Department proposed the inclusion of four performance standards for VRI (which the NPRM termed video interpreting services (VIS)), for effective communication: (1) High-quality, clear...
-
11B-1005.3 Edge protection
platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs or other mobility devices to pull into a clear...
-
11B-304.2 Floor or ground surfaces
Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park...
-
§382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
Question 16
., listening stations for recordings, try-out areas for electronics) clear of obstacles that block floor or knee clearance?...
-
R304.5.1 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
R405 Knee and Toe Clearance (Section-by-Section Analysis)
R405 Knee and Toe Clearance (Section-by-Section Analysis) The technical requirements for knee and toe clearance apply where space beneath an element is included as part of the clear space...
-
§27.71(k)(7)(i) Visibility.
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§ 382.57(c)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
§ 27.71(k)(7)(i) Visibility
The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
5.1.9 Doors
The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4....
-
Scoping [4.1.2(4), 4.1.3(3)]
Requirements in 4.5 apply to accessible routes and spaces, including ramps, elevators, platform lifts, and clear floor space....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
Shower Dimensions for ADA
We would like to confirm this can be interpreted as a nominal dimension rather than a required clear space....