Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
Search Results "Urinal Rim Height"
-
1132A.4 Level floor or landing
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...
-
106.5.51 Public Way
open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear width and height...
-
309 Operable Parts
Specifications for operable parts address clear floor space, height, and operating characteristics. Operable parts are required to be located with the reach ranges specified in 308....
-
407.8.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
4.13.8* Thresholds at Doorways
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
407.12.3 Forward Reach
Where a forward reach allows a reach over a portion of the ICT, the height of that portion of the ICT shall be 34 inches (865 mm) maximum....
-
4.9.2 TREADS AND RISERS
On any given flight of stairs, all steps shall have uniform riser heights and uniform tread widths....
-
4.13.8* THRESHOLDS AT DOORWAYS
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
C. Toilet Rooms:
This reflects at least one (1) such accessible compartment in each accessible toilet room containing six (6) or more toilet compartments or where the combination of urinals and water closets...
-
3. Exception to Ramp Running Slope
As the height of the platform lowers, the length of the ramp can decrease. The trend in the scale industry is to develop lower weight cell technology....
-
1. Desk size
To provide adequate knee and leg clearance, desks and writing tables need to have at least 30 inches of knee width, 29 inches of knee height, and 19 inches of leg depth....
-
705.1.1 Dome Size
a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum to 65 percent of the base diameter maximum, and a height...
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
Forward Approach
Forward Approach A maximum height of 48 inches is required for a forward reach....
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
705.1.1 Dome Size
a base diameter of 0.9 inch (23 mm) minimum and 1.4 inches (36 mm) maximum, a top diameter of 50 percent of the base diameter minimum to 65 percent of the base diameter maximum, and a height...
-
Public Way
open to the outside air leading to a public street, which has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear width and height...
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
provided outside the perimeter of the raised platform and above any edge protection so that patients using a manual wheelchair can extend their arms and elbows when they push on the wheel rims...
- Corbin Russwin Inc. ED4000 Series Narrow Stile Exit Device
- Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
-
407.12.3.2.2 Knee and Toe Space
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
When toilet and bathing facilities have doorway openings instead of doors, such as at airports or stadiums, the geometric identification symbol should be located at the proper height adjacent...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...