The ADA establishes requirements for twelve categories of public accommodations, including stores and shops, restaurants and bars, service establishments, theaters, hotels, recreation facilities...
Search Results "Recreational Surfacing"
-
Private Businesses that Serve the Public: Public Accommodations
- Institute for Community Inclusion - Boston, MA
- Lynx Grills Inc. 30” Grill ProSear Burner & 1 Stainless Steel Burner (L500ADA)
-
Diversified Woodcrafts Oak Table with Book Compartments 24x48
Warranty Made in the USA Manufactured with 2 book compartments measuring 14"W x 13-5/8"D x 3-7/8"H Minimal assembly required; legs need to be attached No Table Surface...
- Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms – Drawing from the U.S. Access Board
- Lynx Grills Inc. 36” Grill - 1 ProSear Burner & 2 Stainless Steel Burners (L600ADA)
-
Standing Supports (M304.3 and M305.3)
Standing Supports (M304.3 and M305.3) M304.3 Proposed Provision: Would require standing supports to be provided on each side of the standing surface on diagnostic equipment used by patients...
-
4.3.2 Clear Floor or Ground Space
Tent pads and tent platforms shall have clear floor or ground space surrounding the tent that is at least 48 inches (1220 mm) wide. This space shall not overlap the...
-
F247.4.4 Routes
Routes that connect trails complying with 1017 to camping facilities, picnic facilities, viewing areas, pit toilets, and accessible elements provided within the facilities shall...
- Lynx Grills Inc. 30” Grill 1 ProSear Burner & 1 Stainless Steel Burner with Rotisserie (L500ADAR)
- Lynx Grills Inc. 36” Grill 1 ProSear Burner & 2 Stainless Steel Burners with Rotisserie (L600ADAR)
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the...
-
1.3 Know Your Rights
Facilities, http://www.access-board.gov/recreation/final.htm ADA & IT Technical Assistance Centers – regional resource centers that provide information on the ADA: http...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
- Ronick Matting Systems BaseMat 300 Entrance Floor Mat
-
Position [§305.5]
For better usability, a forward approach is required at certain elements, including dining and work surfaces, drinking fountains, lavatories, and most sinks....
-
Current Accessibility Guidelines That Apply to the Forest Service
Forest Service Outdoor Recreation Accessibility Guidelines (FSORAG) and Forest Service Trail Accessibility Guidelines (FSTAG)....
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented...
-
Opening Doors From a Wheelchair Video
Requires the Registered User plan or above. Login!
- Boost Your Business - Chapter 7 - Halls and Fountains
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
505.7.2 Non-Circular Cross Sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 6 1/4 inches (160 mm) maximum, and a cross-section dimension...
-
4.4.5 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...