The 1991 Standards require areas of rescue assistance or horizontal exits in facilities with levels above or below the level of exit discharge....
Search Results "Exit Ramp"
-
General
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
1009.6.4 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709 or a horizontal exit complying with Section 1026....
-
USE OF THE WAY
However, the ability of a person with a cognitive disability to use the exits should be verified....
-
Is Identification of the Path(s) to the Means of Egress Necessary?
However, the ability of a person with a cognitive disability to find and use the exits should be verified....
-
Are accessible spaces required on all levels of a multi-level parking structure?
If a parking facility has entrances and exits on one level only, standard and van accessible spaces are required on that level so that they are on the shortest accessible route to the entrance...
-
F238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-238.2.1 Teeing grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-238.2.1 Teeing grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-238.2.1 Teeing grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
Identification [4.3.11.5]
The "AREA OF RESCUE ASSISTANCE" label and access symbol must be illuminated where fire or life safety codes require illuminated exit signs....
- Figure 406.2 Counter Slope of Surface Adjacent to Curb Ramps – Drawing from the U.S. Access Board
-
Turning Space: ADA Standard Section 808.2
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304....
-
238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
11B-106.5 Defined terms
SPORT ACTIVITY ASSEMBLY AREA ASSISTIVE LISTENING SYSTEM (ALS) AUTOMATIC DOOR AUTOMATIC TELLER MACHINE (ATM) BATHROOM BLENDED TRANSITION BOARDING PIER BOAT LAUNCH RAMP...
-
11B-808.2 Turning space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with Section 11B-304....
-
11B-808.2 Turning space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with Section 11B-304....
-
907.2.8 Group R-1
individual guestrooms and contiguous attic and crawl spaces are separated from each other and public or common areas by at least 1-hour fire partitions and each individual guestroom has an exit...
-
240.2.1 Ground Level Play Components
Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide....
-
11B-240.2.1 Ground level play components