Parking Garages Bridge Walkways Bridge Flooring Sidewalks Access to Public/Government Buildings Pedestrian Accessible Roadways Sidewalk Grates Utility Vaults Boat Landing...
Search Results "Elevator Landing"
Commonly Searched Documents
- Aluminum Heavy Duty Wheels n' Heels® InVent Grating
 - 
    
  
  11B-407.2.3 Hoistway signs
  
Signs at elevator hoistways shall comply with Section 11B-407.2.3....
 - 
    
  
  1009.7.2 Separation
  
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
 - 
    
  
  505.10.2 Top Extension at Stairs
  
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
 - 
    
  
  6d. Ramp Length
  
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided every 30 feet of horizontal length?...
 - 
    
  
  11B-233.3.1.2.6.4 Test number three, unusual characteristics test
  
other similar requirements of law or code that require the lowest floor or the lowest structural member of the lowest floor be designed to a specified level at or above the base flood elevation...
 - 
    
  
  11B-410.6 Doors and gates
  
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
 - 
    
  
  1007.7.4 Separation
  
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
 - Aluminum Heavy Duty Wheels n' Heels® Metro Grating
 - 
    
  
  CURB CUT
  
[DSA-AC] An interruption of a curb at a pedestrian way, which separates surfaces that are substantially at the same elevation....
 - 
    
  
  Re: 405 Ramps
  
A ramp with a direction change requires a 60" x 60" minimum intermediate landing, which isn't just a turning space but also a place for stopping to allow for a turn....
 - 
    
  
  Gangway Slope and Rise Exceptions
  
For example, where the vertical distance between where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level is 4 feet, the gangway...
 - 
    
  
  NOSING
  
The leading edge of treads of stairs and of landings at the top of stairway flights....
 - 
    
  
  NOSING
  
The leading edge of treads of stairs and of landings at the top of stairway flights....
 - 
    
  
  Re: Adding an elevator for barrier removal trigger POT upgrades?
  
Readily achievable barrier removal does not trigger additional path of travel work under the ADA. State and local standards and interpretations may vary.
 - 
    
  
  11B-1003.2.1 Boat slips
  
Where gangways connect to transition plates, landings specified by Section 11B-405.7 shall not be required. 6. ...
 - 
    
  
  11B-1003.2.1 Boat slips
  
The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level....
 - 
    
  
  11B-410.1 General
  
Elevator safety is regulated by the California Department of Occupational Safety and Health, Elevator Ride and Tramway Unit - see Title 8, California Code of Regulations for more information...
 - 
    
  
  11B-108 Maintenance of accessible features
  
It is not sufficient to provide features such as accessible routes, parking, elevators, ramps or signage if those features are not maintained in a manner that enables individuals with disabilities...
 - 
    
  
  NOSING
  
The leading edge of treads of stairs and of landings at the top of stairway flights....
 - 
    
  
  R407.7 Surfaces
  
Surfaces of ramp runs and landings shall comply with R302.7....
 - 
    
  
  Gangways
  
Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....
 - 
    
  
  1127B.5, Item 4
  
Level landing. ...