However, if states and local governments choose to use the ADA Standards, the elevator exemption contained in the ADA Standards may not be used 3....
Search Results "Elevated Play Component"
-
Uniform Federal Accessibility Guidelines (UFAS)
- UltraPlay Engineered Wood Fiber Surface
-
§ 35.151(c)(2)
before March 15, 2012, then new construction and alterations subject to this section may comply with one of the following: The 2010 Standards, UFAS, or the 1991 Standards except that the elevator...
-
4.10.6* Door Protective and Reopening Device
Elevator doors shall open and close automatically....
-
4.1.4(1) GENERAL EXCEPTIONS
Accessibility is not required to elevator pits, elevator penthouses, mechanical rooms, piping or equipment catwalks, lookout galleries, electrical and telephone closets, and general utility...
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
409.4.7.4 Cord
The telephone cord shall be 29 inches (735 mm) long minimum.
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with 309.
-
409.4.7.2
The telephone and emergency signaling device shall comply with 309.3 and 309.4.
-
407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309 _|Operable Parts|_.
-
11B-409.4.7.4 Cord
The telephone cord shall be 29 inches (737 mm) long minimum.
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor.
-
407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
409.4.3 Platform to Hoistway Clearance
The clearance between the car platform and the edge of any landing sill shall be 1-½ inch (38 mm) maximum.