The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...
Search Results "Ceramic Tile Flooring"
-
Re: Section 307 Protruding Objects
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-605.5.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
- Olympia i2 Single Handle Diverter Set P-2280
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
Re: Lavatories Adjacent to Partitions
Were the CBC requirement instead made a part of 11B-606.2 (Clear Floor Space), I suppose we'd have to give the notion of "clear" some more thought. ...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
Design Opportunity
27" AFF under the vanity top (306) while keeping the counter/rim at 34" AFF maximum (606.3); and it may require more than 8" minimum knee clearance to provide the extended depth clear floor...