Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
Search Results "Transfer Surface"
Commonly Searched Documents
-
505.4 Height
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Keep wall surfaces above handrails free of any protrusions....
-
F. Swimming Pool Entrance and Deck
(2) Defendants will modify the transfer wall of the outdoor hot tub spa so as to permit access pursuant to 2010 Standards §§ 242.4 and 1009.4....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
M304.2.2 Standing Supports (Section-by-Section Analysis)
The MDE NPRM proposed requiring standing supports on each side of the standing surface of diagnostic equipment used by patients in the standing position, and compliance with the technical...
-
Swimming Pools
The secondary means of entry could be a pool lift, sloped entry, transfer wall, transfer system, or pool stairs. ...
- Diversified Woodcrafts - Forward Vision & Brad (Teacher Series) Promotional Video
- Diversified Woodcrafts Lab Table Assembly Video
- Teknion Journal
- Diversified Woodcrafts 9010 ARM Lab Table Accessory
-
1018.7 Slopes
The slopes of beach access routes shall comply with 1018.7.
-
Running Slope [1017.7.1]
Running slope, also referred to as grade, is the lengthwise slope of a trail, parallel to the direction of travel. Trails or trail segments of any length may be constructed with...
-
1018.7 Slopes
This section contains technical requirements for the maximum running slope and segment length (1018.7.1) and cross slope (1018.7.2) of beach access routes.
-
7.4.3.1 Running Slope (Grade)
The running slope (grade) of trail segments shall comply with this section and shall be consistent over the distances cited. Trail running slope (grade) of up to 1:20 (5...
-
Slope [4.3.7]
Requirements in 4.3, while based on the expectation of level floors, apply equally to exterior sites. Where the running slope of an accessible route exceeds 5% it must be treated as...
-
Changes in Level [4.5.2]
Vertical changes in level up to ¼ inch are permitted without treatment along accessible routes. Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2. Changes...
-
Den
Lamps wired to rocker wall switches Levers on all doors throughout the house FSC certified birdseye and quartersawn maple paneling Zoned heating on...
-
3.1.3.3 Cross Slope of Driveways
The cross slope of driveways shall not exceed 1:33 (3 percent). Exception. The cross slope of driveways may be no more than 1:20 (5 percent) where needed to ensure proper...
-
6.7 Slope
The slopes of beach access routes shall comply with 6.7.1 and 6.7.2