area that is 37 ½ inches long, rather than the required 60 inches, will be supplemented by a platform lift at the North East corner of the pool deck, along with appropriate directional signage...
Search Results "Signage Location"
Commonly Searched Documents
-
F. Swimming Pool Entrance and Deck
-
Facility
All or any portion of buildings, structures, site improvements, elements, and pedestrian routes or vehicular ways located on a site....
-
11B-703.8.13 Brightness
The brightness of variable message signs in exterior locations shall automatically adjust in response to change in ambient light levels....
-
Vertical Dispersion: ADA Standard Section 221.2.3.2
Section 221.2.3.2 covers scoping requirements in the current ADA Standards for vertical dispersion in assembly areas.
-
11B-1008.2.6.2 Use zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition)....
-
4. Overhead PV Systems
For purposes of accessibility compliance, overhead PV systems fall into one of the three following types: 4A – Restricted Access: The PV system is located within a secure enclosure....
-
11B-221.2.3 Lines of sight and dispersion
Wheelchair spaces shall provide spectators with choices of seating locations and viewing angles that are substantially equivalent to, or better than, the choices of seating locations and...
-
Other Boxes: ADA Standard Section 221.2.1.3
Section 221.2.1.3 covers scoping requirements in the current ADA Standards for wheelchair spaces at other boxes not covered under 221.2.1.3.
-
11B-221.2.3.1 Horizontal dispersion
Exceptions: Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required by Section 11B-221.3 and wheelchair spaces are located...
-
11B-220.1 Automatic teller machines and fare machines
Where automatic teller machines or self-service fare vending, collection, or adjustment machines are provided, at least one of each type provided at each location shall comply with 707....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Section 4.1.3, Accessible Buildings: New Construction (Preamble, Section-by-Section Analysis)
storage, shelving, and display units (§ 4.1.3(12)), controls and operating mechanisms (§ 4.1.3(13)), emergency warning systems (§ 4.1.3(14)), detectable warnings (§ 4.1.3(15)), and building signage...
-
Section 4.1.3, Accessible Buildings: New Construction (Section-By-Section Analysis and Response to Comments)
shelving, and display units (Sec.4.1.3(12)), controls and operating mechanisms (Sec.4.1.3(13)), emergency warning systems (Sec.4.1.3(14)), detectable warnings (Sec.4.1.3(15)), and building signage...
-
FACILITY
[DSA-AC] All or any portion of buildings, structures, site improvements, elements, and pedestrian routes or vehicular ways located on a site....
-
Installation: ADA Standard Section 609.7
Section 609.7 covers the current ADA Standards for the installations of grab bars.
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates.
-
Doorways: ADA Standard Section 405.7.5
Section 405.7.5 covers the current ADA Standards for doorway maneuvering clearance at ramp landings.
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-220.1.1 One automatic teller machine or fare machine
Where one automatic teller machine or fare machine is provided at a location, it shall comply with Sections 11B-707.2 through 11B-707.8....
-
III-4.4100 General
Impediments caused by the location of temporary or movable structures, such as furniture, equipment, and display racks, are also considered architectural barriers....
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
Visibility: ADA Standard Section 707.7.1
The display screen shall be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the machine....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....