This section requires the floor surface within camp shelters to be firm and stable and to slope not steeper than 1:48 in any direction....
Search Results "Ramp Slope"
Commonly Searched Documents
-
1014.3 Floor
-
11B-233.3.1.2.6.3 Test number two, site analysis test
Calculate the percentage of the total buildable area of the undisturbed site with a natural grade less than 10 percent slope....
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
Gaps: ADA Standard Section 1002.4.3
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
Develop a Transition Plan
Where a public entity has responsibility or authority over streets, roads, or walkways, its transition plan must include a schedule for providing curb ramps or other sloped areas where pedestrian...
-
11B-705.1.1.4 Resiliency
Exception: Detectable warning surfaces at curb ramps, islands or cut-through medians shall not be required to comply with Section 11B-705.1.1.4....
-
Accessible Ground Surfaces
To meet the standard, the force required must be less than that which is required to propel the wheelchair up a ramp with a slope of 1:14. ...
-
Evaluating the Physical Accessibility of Polling Places
Planning for an upcoming election also gives elections officials the opportunity to improve existing polling places that are not accessible by using temporary elements, such as portable ramps...
-
11B-411.2.1.3.4 Position
Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
11B-411.2.1.3.4 Position
Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
Passing Spaces [1017.4]
Nominally planar means on the same nominal table surface (same nominal geometric surface plane) and the slopes of the table surface correspond to the running slope and cross slope of the...
-
11B-809.8 Doors
Changes in height greater than 1/2 inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 11B-405 or by means of a platform constructed to the level of the floor...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
406.8 Detectable Warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
FIGURE INDEX
Landings Figure 405.9.1 Extended Floor or Ground Surface Edge Protection Figure 405.9.2 Curb or Barrier Edge Protection Figure 406.2 Counter Slope of Surfaces Adjacent to Curb...
-
11B-1002.4.3 Gaps
Exception: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
Baseline
currently provide accessible pedestrian signals and pedestrian pushbuttons when pedestrian signals are newly installed or replaced at signalized intersections Maximum cross slope...
-
704.11.1 Parapet construction
Where the roof slopes toward a parapet at a slope greater than two units vertical in 12 units horizontal (16.7-percent slope), the parapet shall extend to the same height as any portion...
-
1018.1 General
The technical requirements address connections (1018.2); surface (1018.3); clear width (1018.4); obstacles (1018.5); openings (1018.6); slopes, including running slope (1018.7.1) and cross...
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
R409.3 Continuity
Handrails shall be continuous within the full length of each ramp run or stair flight....
-
1017.10 Trailhead Signs
requires trail information signs at trailheads to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and maximum running slope...