Hotels, motels, inns, dormitories, resorts and similar transient lodging facilities shall provide guest rooms in accordance with Sections 11B-224.1 through 11B-224.6....
Search Results "Patient Toilet Room"
Commonly Searched Documents
-
11B-224.1 General
-
9.1.4(2) Equivalent Facilitation
For purposes of this section, it shall be deemed equivalent facilitation if the operator of a facility elects to limit construction of accessible rooms to those intended for multiple occupancy...
-
A. Accessible Guestrooms
in Facility Accessible Rooms Rooms with Roll-in Showers 1 to 25 1 0 26 to 50 2 0 51 to 75 3...
-
11B-224.6 Storage
Fixed or built-in storage facilities within guest rooms required to provide mobility features shall comply with Section 11B-225....
-
4.23.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3...
-
806.1 General
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2....
-
806.1 General
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2....
-
Scoping
Scoping requirements for guest rooms with mobility features and guest rooms with communication features are addressed at section 224.2 and section 224.4, respectively....
-
Guestroom Doors
As a result, persons with disabilities are excluded from accommodations when accessible guestrooms are sold out and also are unable to visit other guests in their rooms....
-
§ 36.304(g)(4)
(4) This requirement does not apply to guest rooms in existing facilities that are places of lodging where the guest rooms are not owned by the entity that owns, leases, or operates the...
-
General rule on reservations. (Section-by-Section Analysis)
They also noted difficulty reserving accessible rooms and the inability to guarantee or otherwise ensure that the appropriate accessible room is available when the guest arrives....
-
11B-806.1 General
Transient lodging guest rooms shall comply with Section 11B-806. Guest rooms required to provide mobility features shall comply with Section 11B-806.2....
-
11B-806.1 General
Transient lodging guest rooms shall comply with Section 11B-806. Guest rooms required to provide mobility features shall comply with Section 11B-806.2....
-
11B-806.1 General
Transient lodging guest rooms shall comply with Section 11B-806. Guest rooms required to provide mobility features shall comply with Section 11B-806.2....
-
Can doors swing into required clear floor or ground space?
clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5) fixture clearances in toilet...
-
M303.2 Wheelchair Spaces
Wheelchair spaces complying with M303.2 shall be provided at diagnostic equipment.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3.
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. EXCEPTION: Options to transfer to or from a mobility device onto...
-
M305.3.3 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to prohibit standing supports from rotating in their fittings. There were no comments on this section and it was not addressed by the MDE Advisory Committee....
-
M303.2 Wheelchair spaces (Section-by-Section Analysis)
This is an introductory section.
-
5.3.3 Transfer Sides Recommendations for M302
5.3.3 Transfer Sides Recommendations for M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to provide...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.