The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
Search Results "Patient Change Area"
-
M302.2.3 Transfer Sides
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
(Significant Changes – Edge Protection), the final rule requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection...
-
11B-231.4.1 Cubicles and counters
Exception: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with Section 11B-231 shall not be required to comply with...
-
11B-231.4.1 Cubicles and counters
Exception: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with Section 11B-231 shall not be required to comply with...
-
11B-231.4.1 Cubicles and counters
Exception: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with Section 11B-231 shall not be required to comply with...
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
All public use and common use areas shall be accessible in compliance with this chapter....
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
All public use and common use areas shall be accessible in compliance with this chapter....
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
All public use and common use areas shall be accessible in compliance with this chapter....
-
11B-221.1 General
Several different types of accessible seating are required in an assembly seating area....
-
11B-221.1 General
Several different types of accessible seating are required in an assembly seating area....
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
In addition, the Access Board has found that the profile of the base components should increase toward the rear of the clearance space where a patient’s foot and toes will be higher than...
-
F246.4 Outdoor Recreation Access Routes
At least one outdoor recreation access route complying with 1016 shall connect accessible parking spaces or other arrival points serving the viewing area with accessible elements, spaces...
-
M301.4.1 Clearance in Base
[See subsections ...]
-
1012.3 Opening limitations
In areas which are not open to the public within occupancies in Group I-3, F, H or S, balusters, horizontal intermediate rails or other construction shall not permit a sphere with a diameter...
-
Golf Facilities: ADA Standard Section 206.2.15
Section 206.2.15 covers scoping requirements in the most current ADA Standards for accessible routes to golf facilities
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
The proposed provision includes technical criteria for changes in level at the entry of a wheelchair space....
-
F202.6.5.5 Assembly Areas
Assistive listening systems shall comply with F219 and assembly seating shall comply with F221.
-
5.3 TABLEWARE AREAS
Install tableware, dishware, condiment, food and beverage display shelves, and dispensing devices in compliance with 4.2 (see Fig. 54).