Penetrations of horizontal assemblies without a required fire-resistance rating shall meet the requirements of Section 707 or shall comply with Sections 711.4.3.1 through 711.4.3.2....
Search Results "Fire Alarm System"
Commonly Searched Documents
-
711.4.3 Nonfire-resistance-rated assemblies
-
711.4.5 Dissimilar materials
Noncombustible penetrating items shall not connect to combustible materials beyond the point of firestopping unless it can be demonstrated that the fire-resistance integrity of the horizontal...
- Bradley 2 Station Verge Lavatory System LVRD2
- Bradley 1 Station Verge Lavatory System LVLD1
- Bradley 3 Station Verge Lavatory System LVLD3
- Horton ProSlideā¢-Blast Sliding Door System
- Bradley 2 Station Verge Lavatory System LVLD2
- Smith System Lift Desk Work Surface with Crank
- Southwest Home Products Window Ease Latching System
- Inclusion Solutions BigBell⢠Max Alert System
- TechnoGymĀ® - Radiant Inclusive Commercial Fitness System
- Bradley 1 Station Verge Lavatory System LVRD1
- Bradley 3 Station Verge Lavatory System LVRD3
- Speakman Versatile Handheld Shower System SM-5040
- Speakman Versatile Handheld Shower System SM-5060
-
11B-504.8 Floor identification
Identification Signs" referenced in CBC 11B-504.8 and in the second paragraph (only) of 1023.9 should not be confused with the "Stairway Identification Signs" (hereinafter termed the "Fire...
-
Where Will the Person(s) Start Providing Assistance?
From the Location of the Person Requiring Assistance Does the person providing assistance need to go where the person with limited mobility is located at the time the alarm sounds?...
-
1008.1.9.7, Item 5
THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM WILL SOUNDā Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm)....
- Unity Surfacing Systems Pave-Land 1 1/2" and 1 3/4" thick Interlocking Tiles
- FindLaw - ADA: Disabilities & Your Rights as an Employee
-
704.6 Structural stability
shall extend to the height required by Section 704.11 and shall have sufficient structural stability such that it will remain in place for the duration of time indicated by the required fire-resistance...
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...
-
704.11.1 Parapet construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost...
- Portable Receiver (BE1033)