A clear ground space shall be provided at the entrance to the camp shelter. ...
Search Results "Wheelchair Space (Assembly)"
-
1014.2.1.1 Clear Ground Space
-
1014.2.1.1 Clear Ground Space
A clear ground space shall be provided at the entrance to the camp shelter....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-705.1.1.2 Dome spacing
11B-705.1.1.2 Dome spacing....
-
304.3.1 Circular Space
304.3.1 Circular Space. The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
- Inpro Corporation ENDURANT® Ceiling Hung Partitions
- Inpro Corporation ENDURANT® Floor-to-Ceiling Mounted Partitions
- Inpro Corporation ENDURANT® Floor-Mounted Overhead-Braced Partitions
-
7.4.11.1 Clear Space
Trailhead signs shall be located centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) minimum clear floor or ground space....
-
11B-902.2.1 Overlap
The clear floor space at dining surfaces shall not overlap the accessible route....
-
Bus Shelters: ADA Standard Section 810.3
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
R404.1 General
Clear spaces shall comply with R404. Advisory R404.1 General....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
Check-Out Aisles: ADA Standard Section 227.2
Section 227.2 covers scoping requirements in the current ADA Standards for check-out aisles.
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section 11B...