Search Results "Side Reach"
- Rebuilding Together Long Beach - Long Beach, CA
-
Entry Doors
Maneuvering clearances on either side of the door that comply with the ADA Standards must be provided....
-
11B-502.6.4.2
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
Plumbing/Restrooms
Mirrors and accessories 11B-603 Clear floor space requirements at fixtures 11B-604 Compartment configuration side...
-
Protruding Objects [4.4]
The touch technique involves arcing the cane side-to-side to detect points beyond both shoulders and is often used in uncontrolled areas....
-
Plumbing/Restrooms
Mirrors and accessories 11B-603 Clear floor space requirements at fixtures 11B-604 Compartment configuration side...
-
11B-1009.5.4 Transfer steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
1009.5.4 Transfer Steps
Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access....
-
§8.27(a)
(a) Owners and managers of multifamily housing projects having accessible units shall adopt suitable means to assure that information regarding the availability of accessible units reaches...
-
Controls [§404.3.5]
The clear floor space is not required to be centered at controls, but should be located to facilitate reach and operation....
-
12. Personal Care Attendant (PCA)
For example, a passenger's request for a transportation entity's driver to remain with the passenger who, due to his or her disability, cannot be left alone without an attendant upon reaching...
-
12. Personal Care Attendant (PCA)
For example, a passenger's request for a transportation entity's driver to remain with the passenger who, due to his or her disability, cannot be left alone without an attendant upon reaching...
-
11B-407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308....
-
Standards that measure needed physical or mental ability to perform a job
However, if a position in a mailroom required as a qualification standard that the person in the job be able to reach high enough to place and retrieve packages from 6-foot high shelves,...
-
1136A.1 Receptacle heights
If the reach is over a physical barrier or an obstruction (for example, a kitchen base cabinet), receptacles shall be located within the reach ranges specified in Section 1138A.3....
-
4.16.6 Dispensers
indicated that nursing staff at Memorial Hospital of Martinsville and Henry County (Martinsville, VA), felt that 24" would provide sufficient space for staff and still permit a patient to reach...
-
1136A.1 Receptacle heights
If the reach is over a physical barrier or an obstruction (for example, a kitchen base cabinet), receptacles shall be located within the reach ranges specified in Section 1138A.3....
-
11B-809.12 Electrical receptacles, controls and switches
Where the reach is over an obstruction, electrical receptacles, controls and switches shall comply with Sections 11B-309.2 and 11B-308.3....
-
R404.7 Maneuvering Space
Where a clear space is confined on all or part of three sides, additional maneuvering space shall be provided in accordance with R404.7.1 and R404.7.2....
-
4. Curb Ramp Width
4. ...are the curb ramps at least 36" wide, excluding the flared sides, to allow for convenient wheelchair travel?...
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....