Alterations and Additions When a building or facility is renovated or altered or added to for any purpose, the alterations or additions must comply with the ADA Standards....
Search Results "Non-Elevator Building"
-
Alterations and Additions
-
Sec.36.401(a) General
(a) General.
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
The Department is proposing § 35.151(d) to clarify that the requirements established by this section, including those contained in the proposed standards, prescribe what is necessary...
-
§ 36.401(a) General
(a) General.
- International Code Council (ICC)
-
III-9.0000 CERTIFICATION
Regulatory references: 28 CFR 36.601-36.608.
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
TEST NO. 1 – INDIVIDUAL BUILDING TEST
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: The slopes of the undisturbed site...
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section...
-
Sec.36.404(a)(2)
(2) For the purposes of this section, shopping center or shopping mall means --
-
§ 36.404(a)(2)
(2) For the purposes of this section, shopping center or shopping mall means –
-
407.2.1.6 Keypads
Where keypads are provided, keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2.
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
409.4.7 Emergency Communications
Emergency two-way communication systems shall comply with 409.4.7.