The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
11B-902.4.2 Height
-
§ 38.25(a) Slip resistance
All aisles, steps, floor areas where people walk and floors in securement locations shall have slip-resistant surfaces....
-
What kinds of treatments constitute maintenance rather than an alteration?
Treatments that serve solely to seal and protect the road surface, improve friction, and control splash and spray are considered to be maintenance because they do not significantly affect...
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302 The Committee recommends adjustable height in small, virtually continuous increments....
-
F240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
- Populas Vox Corner Office Workstation
-
Alterations and Additions
Alterations and Additions When a building or facility is renovated or altered or added to for any purpose, the alterations or additions must comply with the ADA Standards....
-
1016.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
7.4.8 Protruding Objects
Constructed features, including signs, shall not extend into the trail tread more than 4 inches (100 mm) between 27 inches (685 mm) and 80 inches (2030 mm) above the surface of the trail...
-
2.4.2 Cross Slope
Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48 (2 percent). ...
-
1016.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
M302.2.2 Size
The transfer surface shall be 21 inches (610 mm) wide minimum and 15 inches (381 mm) deep minimum. Advisory M302.2.2 Size....
- Pilot Rock ASW-20 Series Grill
-
Sec.36.401(a) General
(a) General.
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
The Department is proposing § 35.151(d) to clarify that the requirements established by this section, including those contained in the proposed standards, prescribe what is necessary...
-
§ 36.401(a) General
(a) General.
-
1011.2.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
1016.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
11B-240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...