Each unisex toilet room shall contain one water closet complying with 4.16 and one lavatory complying with 4.19, and the door shall have a privacy latch....
Search Results "Compartment Door"
Commonly Searched Documents
-
4.1.6(3)(e)(i)
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
7(2)(b)(i)
(i) Where the door swings into the bathroom, there is a clear space (approximately, 2' 6" by 4'0") within the room to position a wheelchair or other mobility aid clear of the path of the...
- Cavity Sliders USA Inc. Wall Mount Track
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
- Behavioral Safety Products #DH510 Mortise Ligature Resistant Integrated Door Lever
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
- Cavity Sliders USA Inc. FH Ceiling Mount Track
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and...
- Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
- Sargent AD8600 & NB-AD8600 Concealed Vertical Rod Exit Device for Aluminum Doors
- Don-Jo Mfg., Inc. Door Flip Guards 1604
- Don-Jo Mfg., Inc. Door Flip Guards 1603
-
T208.2 Connection to Doorways
A passenger access route shall connect each wheelchair space to doorways that provide a means of accessible boarding and alighting in accordance with T208.2.
-
T502.2.1 Over-the-Road Buses
For over-the-road buses, the vertical clearance at doorways shall be 65 inches (1650 mm) minimum.
-
T208 Passenger Access Routes
[See subsections ...]
-
T503.1 General
Illumination shall be provided at ramps, bridgeplates, doorways, and boarding and alighting areas in accordance with T503. Lights shall be shielded so as not to project directly into...
-
§ 35.151(b)(4)(i)(B)
(B) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of...
-
§ 35.151(b)(4)(i)(B)
(B) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, open clothes closet, and door connecting to adjacent guest room. Furnishings include two beds. Â ...
- Nana Wall Systems, Inc. Folding Glass Walls SL45