11B-612.3 Turning space. A turning space complying with Section 11B-304 shall be provided within saunas and steam rooms....
Search Results "Clear Space"
-
11B-612.3 Turning space
-
8.5 Stacks
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
8.5 STACKS
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
Van Accessible Parking Spaces [§502.1 - 502.5]
Van Accessible Parking Spaces [§502.1 - 502.5] At least one space for every 6 or fraction of 6 accessible spaces must be van accessible....
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches....
-
11B-703.2.7 Character spacing
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
T504 Passenger Access Routes
[See subsections ...]
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
206.7.2 Wheelchair Spaces
206.7.2 Wheelchair Spaces....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-703.2.8 Line spacing
11B-703.2.8 Line spacing....
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches....
-
11B-206.4.5 Tenant spaces
[2010 ADAS] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404....
-
11B-206.4.5 Tenant spaces
[2010 ADAS] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404....
-
11B-206.4.5 Tenant spaces
[2010 ADA Standards] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
11B-224.1.2 Guest room doors and doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
-
11B-233.3.1.2.6.5 Additional requirements.
In buildings without elevators and where site impracticality test numbers one, two or three reduce the required number of residential dwelling units with adaptable features, the...