Validity studies not conducted by the user. ...
Search Results "User Control"
Commonly Searched Documents
-
§1607.7 Use of other validity studies.
-
4.3.9 Doorway Design
wheelchair users significantly....
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
EXCEPTION: Visual characters indicating elevator car controls shall not be required to comply with 703.5.6....
-
Stopping Sight Distance
Stopping Sight Distance Adequate sight distance is required to provide path users ample opportunity to see and react to the unexpected....
-
Dimensions: ADA Standard Section 810.2.2
Board’s Note to Reader: The Department of Transportation’s ADA standards indicate that compliance is required to the extent construction specifications are within a public entity's control...
-
Use Zone
is designated by ASTM F 1487 (incorporated by reference, see “Referenced Standards” in Chapter 1) for unrestricted circulation around the play equipment and where it is predicted that a user...
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
Path Width
volumes and passing hindrance resulting from user encounters....
-
4.3.6 Reach Limits
Side reach access is far more preferable to forward reach access, which is quite restricted among the wheelchair user population....
-
Gurney Accessible Bathroom
Movable wall for shower gurney access Vanity remodeled to clear the space for wheelchair users Hand-held shower 6’ hose on shower Shower heads at four...
-
Bails et al.
Scooter users were not included in the study....
-
What values are recommended for ground and floor surfaces along an accessible route?
In the study sponsored by the Access Board, laboratory measurements from a Kistler force plate and computer analysis of the gaits of persons with mobility impairments (including crutch users...
-
Existing Elevators: ADA Standard Section 206.6.1
Section 206.6.1 covers scoping requirements in the most current ADA Standards for accessible routes existing elevators.
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
This data depicts the amount of space required by users of wheeled mobility devices to perform a 180-degree turn....
-
11B-411.2.1.7.2 Assignment by touch screen hall call console
The audio output shall provide verbal instruction for the user to press the accessibility function button as a response to verbal direction in order to select the destination floor....
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
General: ADA Standard Section 208.3.1
Section 208.3.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for parking space locations.
-
11B-505.6 Gripping surface
People with disabilities, older people, and others benefit from continuous gripping surfaces that permit users to reach the fingers outward or downward to grasp the handrail, particularly...
-
1. Abdomen depth (AD)
Within device type, female users had slightly less AD compared to male users....
-
4.3.2 Seat Height
The mean occupied seat heights were 495 mm (19.5 in.) for manual chair users, 538 mm (21.2 inches) for power chair users and 549 mm (21.6 in.) for scooter users....
-
QUESTION: HOW IS A SERVICE ANIMAL CARED FOR WHILE ON BOARD A VESSEL?
ANSWER: * The care of the service animal is the responsibility of its user. The PVO is not responsible for the care or supervision of a service animal....
-
Bathtub Enclosures: ADA Standard Section 607.7
Section 607.7 covers the current ADA Standards for bathtub enclosures.
-
11B-607.7 Bathtub enclosures
Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...