Re: American Standard AccessPRO Toilet
-
407.12 Reach Height
At least one of each type of operable part of stationary ICT shall be at a height conforming to 407.12.2 or 407.12.3 according to its position established in 407.12.1 for a side reach or...
-
Height
Height The transfer wall height must be 16 inches minimum to 19 inches maximum, measured from the deck....
-
HOW TO MEASURE TRANSFER HEIGHTS IS IMPORTANT
HOW TO MEASURE TRANSFER HEIGHTS IS IMPORTANT Many medical examination rooms are equipped with fixed height examination tables, with a typical 32-inch seat height....
-
Height
Height The mounting height of the models worked well for the participants. The models were installed at 39 inches above finished floor to the base....
- Access Board: Alternate Type Roll In Shower Stalls
-
§ 38.107(a)(3)
mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height...
-
407.2.3.2 Car Designations
407.2.3.2 Car Designations. Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor...
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation. Car designations...
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding 2013 CBC requirements pertaining to elevator hoistway signs are more...
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation. Car designations...
-
Stairway Handrails Requirements in the ADA Standards (§504)
Stairway Handrails Requirements in the ADA Standards (§504) Protruding Objects The ADA Standards address hazards posed by protruding objects, such as standpipe...
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
-
11B-407.2.3.2 Reserved
ETA Editor's Note Imposing additional requirements regarding characters and colors, the preceding CBC requirements pertaining to elevator hoistway signs are more stringent...
- Access Board: Tactile Sign Raised Character Requirements
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
11B-233.3.1.2.6.5 Additional requirements.
Water closet seat height complying with Section 11B-809.10.7.4. 7. Electrical receptacles, switches and controls complying with Section 11B-809.12. 8....
-
Handrails [§405.8, §505]
The Standards do not require lower handrails serving children except at ramps serving play areas, but include a recommended height (28” max.) and separation (9” min.) from the required handrail...