To be effective, they should cover the door width, less approximately 2 in (51 mm), up to a height of 16 in (405 mm) from its bottom edge and be centered across the width of the door....
Search Results "Platform Edge"
-
A4.13.9 Door Hardware
-
4.1.6(4)(c)
(i) If a safety door edge is provided in existing automatic elevators, then the automatic door reopening devices may be omitted (see 4.10.6)....
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
§ 38.31(c)
) which, when the door is open, provide at least 1 foot-candle of illumination on the street surface for a distance 3 feet (915 mm) perpendicular to the bottom step tread or lift outer edge...
- Kompan, Inc. Rock-it GXY934
-
Base Support [No specific provision—affects M303.2.4]
The footrest depth is the horizontal distance from the abdomen to the distal (forward-most) edge of the footrest....
- The Viscardi Center
-
§ 38.71(b)(2)
(2) Vehicles designed for, and operated on, pedestrian malls, city streets, or other areas where level boarding is not practicable shall provide wayside or car-borne lifts, mini-high platforms...
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
Men’s toilet and bathing facilities shall be identified by an equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
1009.2.3 Clear Deck Space
The space shall be 36 inches (915 mm) wide minimum and shall extend forward 48 inches (1220 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
Built-up Curb Ramps [4.7.6]
Recommendation: Curb ramps with returned sides or concave flares are preferred over built-up curb ramps with convex flares because they provide greater edge protection....
-
Door Closers [4.13.10]
period of the closer be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches from the latch, measured to the leading edge...
-
Protruding Objects [4.31.4]
Enclosures with a bottom edge that is within 27 inches from the floor or ground are detectable by cane....
-
Original research for ANSI A117.1 (1957 - 1961)
Specifications for Making Buildings and Facilities Accessible to, and Usable by, the Physically Handicapped, ramps were assessed for flatness based on measuring 18 - inch increments on both edges...
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
11B-1009.2.3 Clear deck space
The space shall be 36 inches (914 mm) wide minimum and shall extend forward 48 inches (1219 mm) minimum from a line located 12 inches (305 mm) behind the rear edge of the seat....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
- Activar JL Industries Ambassador Series 1017F10 Steel Fire Extinguisher Cabinets
-
11B-106.5 Defined terms
OCCUPIABLE SPACE OPEN RISER OPERABLE PART PASSENGER ELEVATOR PATH OF TRAVEL PEDESTRIAN PEDESTRIAN WAY PERMANENT PERMIT PICTOGRAM PLACE OF PUBLIC ACCOMMODATION PLATFORM...