alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these spaces where ramp...
Search Results "Exterior Ramp"
Commonly Searched Documents
-
11B-808.3 Clear floor space
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
Accessible Entrance
When a ramp is added to provide an accessible entrance, the slope of the ramp should be as shallow as possible but not more than 1:12....
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADAS] 210.1 General. ...
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADAS] 210.1 General. Interior and exterior stairs that are part of a means of egress shall comply with 504....
-
11B-404.2.4.1 Swinging doors and gates
Add 6 inches (152 mm) at exterior side of exterior doors....
-
11B-404.2.4.1 Swinging doors and gates
Add 6 inches (152 mm) at exterior side of exterior doors....
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADA Standards] 210.1 General....
-
Issue 2: Location relative to the crosswalk
Figure 5: APS is located about 8 feet from the crosswalk and curb ramp landing....
-
Accessible Slopes
For a ramp the maximum running slope allowed is 1:12. That means for every inch of height change there should be at least 12 inches of ramp run....
-
F216.13 Trailhead Signs
Tactile characters are not required on exterior signs. Trail information signs are not required to display the International Symbol of Accessibility....
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
-
COMMON USE
Interior or exterior circulation paths, rooms, spaces or elements that are not for public use and are made available for the shared use of two or more people....
-
COMMON USE
Interior or exterior circulation paths, rooms, spaces or elements that are not for public use and are made available for the shared use of two or more people....
-
5. Grievance Procedure
In April 2008, the City installed the curb ramps per Kirola's request. RT 1383:19-1884:8, 1391:18-1392:2....
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
DETECTABLE WARNING
Curb ramps remove the needed cues for persons with visual impairments; detectable warnings have been developed as a replacement cue and warning to indicate the presence of a vehicular way...
-
Elevated Play Components
Play areas with 20 or more elevated components must use ramps to connect a minimum of 25 percent of those components. ...
-
1133B.5.4.5
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.5 Ramps. 1133B.5.4.5 Landing width. ...
-
11B-206.2.1 Site arrival points
.) ◼ [ADA Title II] §35.151(i) New Construction and Alterations; Curb Ramps....
-
Handrails Along Walkways
The 1991 Standards do not contain any technical requirement for handrails provided along walkways that are not ramps....
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....