A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground...
Search Results "Zero Curb Transition"
Commonly Searched Documents
- 
    
  
  405.9.2 Curb or Barrier
  
 - 
    
  
  11B-405.9.2 Curb or barrier
  
A curb, 2 inches (51 mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102...
 - 
    
  
  Curbs [4.21.7]
  
Curbs [4.21.7] Curbs are not permitted at roll-in showers. A slope up to 2% is allowed for drainage....
 - 
    
  
  11B-406.5.10 Diagonal curb ramps
  
Diagonal or corner type curb ramps are perpendicular or parallel curb ramps that are oriented diagonally at an intersection....
 - 
    
  
  1.9.1.1.4
  
1.9.1.1.4 With respect to buildings, structures, sidewalks, curbs and related facilities not requiring a building permit, building standards published in the California Building Standards...
 - 
    
  
  Parallel Curb Ramps
  
Curb ramps can be oriented parallel to sidewalks. This design provides an option where limited space precludes a top landing....
 - 
    
  
  11B-405.9.2 Curb or barrier
  
A curb, 2 inches (51 mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102...
 - 
    
  
  11B-405.9.2 Curb or barrier
  
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
 - 
    
  
  DSA Drawing 11B-406-7 Parallel Curb Ramp next to a Curb and Gutter (2016 CBC)
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  DSA Drawing 11B-406-9 Parallel Curb Ramp next to a Curb and Gutter (2016 CBC)
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  11B-705.1.2.2.2.1 One entrance/exit point
  
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
 - 
    
  
  Can curbs be used to indicate areas with less than 80” of vertical clearance?
  
Curbs may be mistaken for a step or change in level, instead of a barrier....
 - 
    
  
  Curb Ramp Requirements [§406]
  
Curb Ramp Requirements [§406]...
 - 
    
  
  DSA Drawing 11B-406-11 Diagonal Curb Ramp next to a Curb and Gutter (2016 CBC)
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - 
    
  
  11B-303.5 Warning curbs
  
changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs...
 - 
    
  
  4.1.6(1)(b)
  
requirements) requiring major structural changes are planned or installed where none existed previously, then a means of accessible vertical access shall be provided that complies with 4.7, Curb...
 - 
    
  
  4. Curb Ramp Width
  
4. ...are the curb ramps at least 36" wide, excluding the flared sides, to allow for convenient wheelchair travel?...
 - 
    
  
  DSA Drawing 11B-406-5 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
  Requires the Premium User plan or above. (Login or upgrade your account!)
 - Part 1: How to create an ADA Transition Plan
 - Part 2: How to perform an ADA Transition Plan
 - Part 3: How to perform an ADA Transition Plan
 - 
    
  
  Transition Plate
  
A sloping pedestrian walking surface located at the end(s) of a gangway.
 - 
    
  
  TRANSITION PLATE
  