Characters shall use fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
Search Results "Visually Discernible"
-
T702.3 Character Proportions
-
T702.2 Character Style
Characters shall be displayed in sans serif fonts and shall not use italic, oblique, script, highly decorative, or other unusual forms.
-
T702.4 Character Height
Character height shall comply with Table T702.4. Character height shall be based on the uppercase letter “I”. Table T702.4—Character Height Sign...
-
4.28.3(4)
(4) The intensity shall be a minimum of 75 candela.
-
§27.71(k)(6)(ii) Alphabetic keys.
(ii) Alphabetic keys. Alphabetic keys must be arranged in a QWERTY keyboard layout. The “F” and “J” keys must be tactilely distinct from the other keys.
-
§ 27.71(k)(6)(ii) Alphabetic keys
(ii) Alphabetic keys. Alphabetic keys must be arranged in a QWERTY keyboard layout. The “F” and “J” keys must be tactilely distinct from the other keys.
- Alertus Desktop Notification
-
Building Directories
Question: We have a five-story office building that is three years old. Since the building opened, there have been complaints that the directory's tenant names in our Lobby are hard...
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
Paragraph (c) (Advisory Guidance)
Depending upon the product, the manufacturer may also be able to allow users to adjust colors to match their preferences and visual abilities. d. Avoid colors with a low luminance....
-
302.2 With Limited Vision
Where a visual mode of operation is provided, ICT shall provide at least one mode of operation that enables users to make use of limited vision....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be...
-
907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
Employee Work Areas: ADA Standard Section 215.3
Section 215.3 covers scoping requirements in the current ADA Standards for fire alarm systems in employee work areas.
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other...
-
907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other...
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems.
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be...