SENSORY PROVISIONS
SENSORY PROVISIONS Usable without ability to hear product Provide all auditory information necessary to use the product through at least one mode in visual form....
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5.
-
11B-703.5.9 Line spacing
Visual character line spacing not addressed by 2010 and earlier versions of CBC, or by 1991 ADAAG.]...
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.5.1 Finish and Contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
T702.6 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
T702.7 Line Spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
T702.3 Character Proportions
Characters shall use fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
T702.2 Character Style
Characters shall be displayed in sans serif fonts and shall not use italic, oblique, script, highly decorative, or other unusual forms.
-
T702.4 Character Height
Character height shall comply with Table T702.4. Character height shall be based on the uppercase letter “I”. Table T702.4—Character Height Sign...
-
4.28.3(4)
(4) The intensity shall be a minimum of 75 candela.
-
11B-707.7.2 Characters
Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I". Characters shall contrast...
-
Employee Work Areas: ADA Standard Section 215.3
Section 215.3 covers scoping requirements in the current ADA Standards for fire alarm systems in employee work areas.
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems.
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be...
-
907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
402.4 Characters on Display Screens
At least one mode of characters displayed on the screen shall be in a sans serif font....
-
402.4 Characters
At least one mode of characters displayed on the screen shall be in a sans serif font....
-
C. Communication Features
Yes __ No __ N/A __ Comments: ________________________________________ Visual notification device for door knocks and phone calls (Cannot be same strobe as the fire alarm strobe unit)...