The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
Search Results "Turning Space"
Commonly Searched Documents
-
304.3.1 Circular Space
-
304.3.2 T-Shaped Space
304.3.2 T-Shaped Space. The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
- Figure 403.5.2 Clear Width at Turn – Drawing from the U.S. Access Board
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
H7
Inside the toilet room, is there an area where a person who uses a wheelchair or other mobility device can turn around - either at least 60-inch diameter circle or a “T”-shaped turn area...
-
11B-304.3.2 T-Shaped space
The turning space shall be a T-shaped space within a 60 inch (1524 mm) square minimum with arms and base 36 inches (914 mm) wide minimum....
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
1016.8.4 Turning Space
This section requires a turning space complying with 304.2.3 of the Architectural Barriers Act Accessibility Guidelines where resting intervals are provided adjacent to an outdoor recreation...
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
A4.23.3 Clear Floor Space
Since the shower does not have a lip, the floor space can be used for required maneuvering space....
-
Passing Spaces on Trails
Passing spaces must be at least 60 inches (1,525 millimeters) wide (including the trail width) by 60 inches (1,525 millimeters) long (figure 134)....
-
Appropriate clear floor space
Appropriate clear floor space (shown by dashed lines) is needed adjacent to each cell feature (see page 1 diagrams on clear floor space)....
-
11B-304.3.2 T-Shaped space
The turning space shall be a T-shaped space within a 60 inch (1524 mm) square minimum with arms and base 36 inches (914 mm) wide minimum....
-
11B-304.3.2 T-Shaped space
The turning space shall be a T-shaped space within a 60 inch (1524 mm) square minimum with arms and base 36 inches (914 mm) wide minimum....
-
4.22.3 CLEAR FLOOR SPACE
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible toilet room....
-
4.22.3* Clear Floor Space
An unobstructed turning space complying with 4.2.3 shall be provided within an accessible toilet room....
-
4.5 Maneuvering Clearances
“U-Turn” for All Devices Only the U.S. and Canada have requirements for 90 degree or L-Turn clearances. All the standards have requirements for “wheelchair turning spaces.”...
-
M6
Inside the room is there an area for a person who uses a wheelchair to turn around - either a 60-inch diameter circle or a “T”-shaped turn area?...
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....