11B-703.5.9 Line spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
Search Results "Toilet Room Signage"
-
11B-703.5.9 Line spacing
-
11B-703.1.1 Plan review and inspection
11B-703.1.1 Plan review and inspection. Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or...
-
11B-703.1.1.2 Inspection
11B-703.1.1.2 Inspection. Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final...
-
11B-703 Signs
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
Signage
Error/Omission: Where permanent room identification signage is provided, it is mounted in the wrong location....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Toilet Rooms....
-
Attachment E
Remove the sign designating this toilet room as accessible to persons with disabilities. Redesignate the men’s and women’s staff toilet rooms as the accessible toilet rooms. ...
-
Signs: ADA Standard Section 703
-
General: ADA Standard Section 703.1
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
Installation Height and Location: ADA Standard Section 703.4
Signs with tactile characters shall comply with 703.4.
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
Visual Characters: ADA Standard Section 703.5
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.