The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
Search Results "Stair Handrail"
-
11B-1009.6.2 Handrails
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
Pricilla Rogers, Ph.D., Center on Vision Loss, American Foundation for the Blind
Stairs (slide 9) Color contrasting rails including extensions. Contrast and texture on the edge of steps (contrast covered by ANSI; not by ADAAG)....
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
1009.6.2 Handrails
1009.6.2 Handrails. The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum....
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
Handrails: ADA Standard Section 1009.6.2
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
1009.15 Handrails
1009.15 Handrails. ......
-
11B-504.6 Handrails
Stairs shall have handrails complying with Section 11B-505....
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
11B-505.2 Where required
Handrails shall be provided on both sides of stairs and ramps. Exceptions: 1. ...
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
11B-505.7 Cross section
Handrail gripping surfaces shall have a cross section complying with Section 11B-505.7.1 or 11B-505.7.2....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.9 Fittings
Handrails shall not rotate within their fittings....
-
11B-505.10 Handrail extensions
Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg stairs and ramps. 2. ...
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....