11B-308.3 Side reach
-
Spring Hinges: ADA Standard Section 404.2.8.2
Section 404.2.8.2 covers the current ADA Standards for door and gate spring hinges.
- Set Up and Adjustment of a PDQ Door Closer
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
No, compliance is not required on both sides of those doors or gates that can be used in one direction only. Compliance is required only on the usable side....
-
OPEN RISER
The space between two adjacent stair treads not closed by a riser.
-
OPEN RISER
The space between two adjacent stair treads not closed by a riser.
-
Doors, Doorways, and Gates: ADA Standard Section 206.5
Section 206.5 covers scoping requirements in the most current ADA Standards for accessible routes to doors, doorways, and gates.
-
Toilet Rooms-Special Exhibit Space
The force required to push or pull open the restrooms' vestibule doors is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). v....
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
-
Swinging Doors: ADA Standard Section 408.3.2
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator swinging doors.
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
3. Measuring Door Openings
Measuring Door Openings Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
- Open Sesame Remote Controlled Low-Voltage Door System
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
1018.6 Openings
This section requires openings in the surface of beach access routes and resting intervals such as spaces between boards to not allow passage of a sphere more than 1/2 inch in diameter....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
Double-Leaf Doors and Gates: ADA Standard Section 404.2.2
Section 404.2.2 covers the current ADA Standards for double-leaf doors and gates that are part of an accessible route.
-
Unobstructed: ADA Standard Section 308.3.1
Section 308.3.1 covers the current ADA Standards for unobstructed side reach.
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
Manual Doors, Doorways, and Manual Gates: ADA Standard Section 404.2
Section 404.2 covers the current ADA Standards for manual doors, doorways and manual gates that are part of an accessible route.
-
Door Swing: ADA Standard Section 803.3
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....