Companion seats shall comply with Section 11B-802.3....
Search Results "Patient Seated in Wheelchair"
-
11B-802.3 Companion seats
-
11B-802.3 Companion seats
Companion seats shall comply with Section 11B-802.3....
- Exam Tables & Scales: What Patients Say...
-
M101.2 Application (Section-by-Section Analysis)
The first is to exempt examination chairs which comply with M302 and can be reclined to facilitate diagnosis after the patient transfers onto the seat from complying with M301....
-
Seating
[See subsections ...]
-
Location and Size
supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated position: • At least one transfer support would be provided on the side of the transfer surface...
-
5.4.3 Transfer Support Height for M301 and M302
Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used by patients...
-
1002.4.7 Companion Seats
1002.4.7 Companion Seats....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
- Brewer 3000 LiftMate Low / High Patient Lift
-
WHEELCHAIR
[ADA Title II §35.104] Wheelchair means a manually-operated or power-driven device designed primarily for use by an individual with a mobility disability for the main purpose of indoor or...
-
WHEELCHAIR
[ADA Title II §35.104] Wheelchair means a manually-operated or power-driven device designed primarily for use by an individual with a mobility disability for the main purpose of indoor or...
-
1002.4.7 Companion Seats
Where the interior width of the amusement ride is greater than 53 inches (1345 mm), seating is provided for more than one rider, and the wheelchair is not required to be centered within...
-
1002.4.7 Companion Seats
Where the interior width of the amusement ride is greater than 53 inches (1345 mm), seating is provided for more than one rider, and the wheelchair is not required to be centered within...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
The limitation on edge protection height will reduce the possibility that the edge protection will interfere with the patient’s footrest. 5.8.1.2.2 Single Ramp Scale with Edge Protection...