  Inclusive Safety Briefing
  
- 
    
  
  4.1.2 Surface Design of Examination Tables and Chairs
  4.1.2 Surface Design of Examination Tables and Chairs For several reasons including patient comfort and safety, the surfaces of many examination tables and chairs are not flat.... 
- 
    
  
  36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM
  The proposed standards contain minimum technical criteria to ensure that medical diagnostic equipment, including examination tables, examination chairs, weight scales, mammography equipment... 
- 
    
  
  M305.2.2 Length
  The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2. 
- 
    
  
  B. Information about the Aircraft
  You should be familiar with and be able to provide information about aircraft accessibility for passengers with a disability when they request this information. [Secs. 382.21 and... 
- 
    
  
  5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
  The provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M301.2.3 and M302.2.3 Transfer Sides.... 
- 
    
  
  36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
  The proposed standards contain minimum technical criteria to ensure that medical diagnostic equipment, including examination tables, examination chairs, weight scales, mammography equipment... 
- 
    
  
  M305.2.8 Fittings
  Transfer supports shall not rotate within their fittings when in place for transfer. 
- 
    
  
  M305.2.7 Clearance
  Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum. 
- 
    
  
  M305.2.7 Clearance (Section-by-Section Analysis)
  In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board... 
- 
    
  
  5.4.10 Transfer Support Fittings Recommendations for M301 and M302
  5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings... 
- 
    
  
  5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer supports shall not rotate when locked in place for patient... 
- 
    
  
  Attachment A: Disability-Related Issues for Emergency Plan Coordinators
  (Give a copy of this checklist to personnel who are responsible for creating, reviewing, maintaining, practicing and revising emergency plans.) DISABILITY-RELATED ISSUES FOR... 
- 
    
  
  M305.2.3 Fittings
  Transfer supports shall not rotate within their fittings. 
- Brewer Access™ High-Low Exam Table
- Midmark 623 Barrier-Free® Power Examination Table
- Midmark 625 Barrier-Free® Power Examination Table
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Midmark Ritter 223 Barrier-Free® Power Examination Table
- 
    
  
  M305.2.1 Location
  Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the... 
- 
    
  
  M305.2.4 Cross Section
  Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2. 
- 
    
  
  M305.2.3 Height
  During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed... 
- 
    
  
  M305.2.6 Gripping Surface
  Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of transfer support gripping surfaces... 
- 
    
  
  M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
  The proposed rule did not provide any specific requirements regarding gripping surfaces on transfer supports. However, in the MDE NPRM preamble the Access Board repeatedly noted that... 