Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
Search Results "Lavatory Height"
Commonly Searched Documents
-
Counter Surface Height
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
Technical Memorandum TM 2013-19 Private Toilet and Bathing Rooms
Lavatories and Sinks 606.2, Exception 2: Clear Floor Space 606.3, Exception 1: Height. Bathtubs 607.4, Exception 1: Grab Bars....
-
605.2 Height and Depth
605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use....
-
Overlapping Clear Floor Space
Specifications for roll-in shower compartments indicate that an accessible lavatory can overlap the required clear floor space opposite the end with a seat and shower controls (608.2.2)....
-
4.19.3 Clear Floor Space
A clear floor space 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a lavatory to allow forward approach....
-
4.19.3 CLEAR FLOOR SPACE
A clear floor space 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a lavatory to allow forward approach....
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5....
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground.
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel...
-
1008.2.5.3.2 Handrail Height
1008.2.5.3.2 Handrail Height. The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
5. Clear floor space
Clear floor space is needed for a forward approach to the lavatory....
-
(1) Adjustability: Minimum High Transfer Height
Another manufacturer gave examples of the height ranges of its beds and stretchers, each of which met the 25-inch minimum high height....
-
605.2 Height and Depth
[ECTCR UFAS 4.18.2] Figure 605.2 Height and Depth of Urinals...
-
902.4.2 Height
902.4.2 Height. The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
Transfer Height
Transfer Height Ride seats designed for transfer must be between 14 and 24 inches above the load and unload area surface....
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
4.18.2 Height
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the finish floor.