Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
Search Results "Grab Bar Reinforcement"
Commonly Searched Documents
-
Clear Deck Space: ADA Standard Section 1009.4.1
-
11B-1009.4.1 Clear deck space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided....
- AJW Architectural Products US130-A Series US130-A12 12" Exposed Flange, 1.5" Diameter Security Grab Bar - Configuration A
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
- Mega Jailhouse Anti-Suicide Grab Bar with Closure Plate 36 inches - Concealed Mounting
-
Grab Bar Cross Sections
The Board has clarified that the space between grab bars and projecting objects below and at the ends shall be 1 ½ inches minimum, consistent with criteria for water closets, tubs, and showers...
-
11. Gap
Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so the arm...
-
8. Gap
Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so the arm...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-604.8.2.3 Grab bars
11B-604.8.2.3 Grab bars. Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
Location
When this grab bar was used (e.g....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
- AJW Architectural Products UG130-A Series UG130-A12 12" Exposed Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG120-A Series UG120-A12 12" Exposed Flange, 1.25" Diameter Grab Bar - Configuration A
- Moen Stainless 30" Grab Bar
-
11B-604.9.4 Grab bars
11B-604.9.4 Grab bars. Grab bars for water closets shall comply with Section 11B-604.5....
- Comfort Designs Tamper Proof Anti-ligature Grab Bars