Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates.
Search Results "Gate"
Commonly Searched Documents
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADA Standards] 404.2.9 Door and Gate Opening Force....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
Power-Operated Doors or Gates
Platform lifts are required to have power-operated doors or gates....
-
11B-410.6 Doors and gates
End doors and gates shall provide a clear width 32 inches (813 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1067 mm) minimum....
-
Doors and Gates in Series [§404.2.6]
Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
Recessed Doors and Gates [§404.2.4.3]
Recessed Doors and Gates [§404.2.4.3] Thick walls, casework, shelving, columns and other elements can cause doors or gates to be recessed....
-
404.2.4.3 Recessed Doors and Gates
404.2.4.3 Recessed Doors and Gates....
-
10.4 Airports
[See subsections ...]
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
404.2.10 Door and Gate Surfaces
404.2.10 Door and Gate Surfaces....
-
404.2.4.3 Recessed Doors and Gates
obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate...
-
Door and Gate Hardware
Section 404.2.7 also covers the operating characteristics and height of door and gate hardware....
-
404.2.4.1 Swinging Doors and Gates
404.2.4.1 Swinging Doors and Gates. Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
404.2.6 Doors in Series and Gates in Series
404.2.6 Doors in Series and Gates in Series....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
404.2.7 Door and Gate Hardware
404.2.7 Door and Gate Hardware. Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
404.2.4.3 Recessed Doors and Gates
obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate...
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.