• Each bank of public telephones must have one or more wheelchair accessible telephones and these and other public telephones must have the ability to amplify the volume at the handset....
Search Results "Exterior Telephone"
Commonly Searched Documents
-
Each bank of public telephones must have one or more wheelchair accessible telephones and these and other public telephones must have the ability to amplify the volume at the handset.
-
11B-704.2.4 Cord length
The cord from the telephone to the handset shall be 29 inches (737 mm) long minimum....
-
1132A.2 Interior doors and secondary exterior doors
1132A.2 Interior doors and secondary exterior doors....
-
1003.2.13.7.1 Openness
The exterior area of refuge shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases....
-
217.3 Volume Controls
All public telephones shall have volume controls complying with 704.3....
-
1007.8.1 Openness
The exterior area for assisted rescue shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases...
-
11B-217.3 Volume controls
All public telephones shall have volume controls complying with Section 11B-704.3....
-
11B-217.3 Volume controls
All public telephones shall have volume controls complying with Section 11B-704.3....
-
11B-217.3 Volume controls
All public telephones shall have volume controls complying with Section 11B-704.3....
-
217.3 Volume Controls
All public telephones shall have volume controls complying with 704.3....
-
F217.3 Volume Controls
All public telephones shall have volume controls complying with 704.3. [ECTCR UFAS 4.1.2(16)(b)]...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
1007.7.5 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
A4.1.3(17)(b)
Volume controls may be installed on any telephone....
-
§ 37.43(f)(2)(iv)
(iv) Accessible telephones;...