11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
4.13.11* DOOR OPENING FORCE
The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
Accessible Means of Entry to Spas
Accessible Means of Entry to Spas....
-
A4.13.11 Door Opening Force
Although some people cannot manage the allowable forces in this guideline and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
A4.13.11 DOOR OPENING FORCE
Although some people cannot manage the allowable force in this standard and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
404.2.4.2 Doorways without Doors or Gates
Sliding Doors, and Folding Doors....
-
Swimming Pools: ADA Standard Section 242.2
Section 242.2 covers scoping requirements in the current ADA Standards for swimming pools.
-
11B-242.2 Swimming pools
At least two accessible means of entry shall be provided for swimming pools....
- EZ-ACCESS Transitions® Modular Entry Mat
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
- Figure 1009.3.2 Sloped Entry Submerged Depth – Drawing from the U.S. Access Board
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
A4.17.5 DOORS
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
- EZ-ACCESS Transitions® Modular Entry Ramp
-
General: ADA Standard Section 1009.1
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
C. Doors
Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within...