Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
Search Results "Elevator Door Timing"
-
409.3.1 Power Operation
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
Elevator doors shall open and close automatically....
-
Inside Dimensions of Elevator Cars: ADA Standard Section 409.4.1
Section 409.4.1 covers the current ADA Standards for the inside dimensions of private residence elevator cars.
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors shall comply with this section and Section 11B-809.8....
-
Preserving elevator access in building where it might not be required.
Each story less than 3000 square feet, so elevator would likely not be required if built new. 2010 Standards 206.2.3, Exception 1. ...
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
408.3.1 Sliding Doors
408.3.1 Sliding Doors. Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
408.3.2 Swinging Doors
408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Doors in Series and Gates in Series: ADA Standard Section 404.3.4
Section 404.3.4 covers the current ADA Standards for doors in series and gates in series at automatic and power-assisted doors and gates.
-
408.3.1 Sliding Doors
Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
408.3.1 Sliding Doors
Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
- Otis Elevator Advanced Lantern Retrofit
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
Revolving Doors, Revolving Gates, and Turnstiles: ADA Standard Section 404.3.7
Section 404.3.7 covers the current ADA Standards for revolving doors, revolving gates, and turnstiles.
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....