Search Results "Drinking Fountain Spout Height"
- Willoughby Industries WODF-1WM Wall Mounted A.D.A. Stainless Steel Outdoor Drinking Fountain
-
Forward Approach
The Board sought comment on whether it should require a forward approach, which includes knee and toe clearances below the unit, at all wheelchair accessible drinking fountains (Question...
-
Willoughby Industries WODF-3-HC-PET Stainless Steel Outdoor ADA and Pet Drinking Fountain
Requires the Premium User plan or above. (Login or upgrade your account!)
- Boost Your Business - Chapter 7 - Halls and Fountains
-
J5
J5. Are the controls on or near the front of the unit and do they operate with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards §...
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
11B-602.9 Pedestrian protection
All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways....
-
J1
If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
- 309.4 Accessible Low Drinking Fountain Operation
-
§ 35.151(b)(4)(iii)(B)(4)
(4) Costs associated with relocating an inaccessible drinking fountain....
-
§ 37.43(e)(2)(iv)
(iv) Costs associated with relocating an inaccessible drinking fountain....
- Willoughby Industries WODF-3-HC-CHD Stainless Steel Outdoor ADA and Child Drinking Fountain
-
§ 35.151(b)(4)(ii)(B)
(B) For the purposes of this section, the term path of travel also includes the restrooms, telephones, and drinking fountains serving the altered area....
-
§ 35.151(b)(4)(ii)(B)
(B) For the purposes of this section, the term “path of travel” also includes the restrooms, telephones, and drinking fountains serving the altered area....
- ELKAY EZH2O® Bottle Filling Station with Integral SwirlFlo® Fountain EZWS-EDFPBM117K
-
Forward Approach
Forward Approach Drinking fountains are easier to use from a forward approach than from a side approach. Clearances for a forward approach are required at cantilevered units....
-
10. Drinking fountains and water coolers
Drinking fountains and water coolers 4.15 Fifty percent of fountains and coolers on each floor, or at least one, if provided in the facility or the site....
-
Willoughby Industries CWBF-2 Stainless Steel Outdoor Bottle Filler With Drinking Fountain
Requires the Premium User plan or above. (Login or upgrade your account!)
- ELKAY Filtered EZH2O® Bottle Filling Station with Integral Soft Sides® Fountain LZWS-EDFP217K
-
Height: ADA Standard Section 604.9.3
Section 604.9.3 covers the current ADA Standards for the height of children's use water closets.
- ELKAY Filtered EZH2O® Bottle Filling Station with SwirlFlo® Green Bi-Level Refrigerated Fountain LZWS-SFGRN28K
-
Height: ADA Standard Section 903.5
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground.