Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
Search Results "Distinct Viewing Location"
-
11B-703.8.4 Character height
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
Multi-Level Parking Garage Not Serving a Particular Facility
Accessible spaces, including van spaces, must be located so that they provide the same level of protection and security as other spaces in the garage....
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
F245.4.4 Location
This section requires outdoor recreation access routes to coincide with or be located in the same general area as general circulation paths....
-
F244.5.4 Location
This section requires outdoor recreation access routes to coincide with or be located in the same general area as general circulation paths....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
1015.6 Slope
The slope of the surface of clear ground spaces and turning spaces shall not be steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than asphalt, concrete,...
-
1015.5 Surface
This section requires the surface of the clear ground space and turning space to be firm and stable.
-
1015.6 Slope
The slope of the surface of clear ground spaces and turning spaces shall not be steeper than 1:48 in any direction. EXCEPTION: Where the surface is other than asphalt, concrete,...
-
F247.4.4 Routes
Routes that connect trails complying with 1017 to camping facilities, picnic facilities, viewing areas, pit toilets, and accessible elements provided within the facilities shall comply with...
-
208.1.2
If compliance with parking location requirements is not feasible, the facility may provide parking spaces at alternative locations for persons who have disabilities and provide appropriate...
-
Control End Wall: ADA Standard Section 607.4.2.2
Section 607.4.2.2 covers the current ADA Standards for grab bars on the control end of bathtubs without permanent seats.
-
Head End Wall: ADA Standard Section 607.4.2.3
Section 607.4.2.3 covers the current ADA Standards for grab bars on the head end wall of bathtubs without permanent seats.
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub.
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub.
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
-
Control End Wall: ADA Standard Section 607.4.1.2
Section 607.4.1.2 covers the current ADA Standards for grab bars on the control end of bathtubs with permanent seats.
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.