Search Results "Clear Opening"
Commonly Searched Documents
- Figure 403.5.1 Clear Width of an Accessible Route – Drawing from the U.S. Access Board
-
7d.
Is no more than 5 pounds force needed to push or pull open the accessible door?...
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
When the surface of the clear ground space is constructed of concrete, asphalt, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
g-iv
Is no more than 5 pounds force needed to push or pull open the door?...
- Hager Companies Three Knuckle - Full Mortise Swing Clear Hinge AB7001
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
6.14.1 Clear Width
Gate openings and openings in barriers for pedestrian passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width....
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. Advisory 11B-1008.4.2 Clear floor or ground space....
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
CLEAR
CLEAR. [DSA-AC] Unobstructed....
-
Clear With [sic] [§404.2.3]
Clear With [sic] [§404.2.3] The clear width is measured from the stop to the face of doors or gates open 90⁰ (or to the leading edge of sliding or folding doors....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Forced applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
Floor or Ground Surfaces: ADA Standard Section 305.2
Section 305.2 covers the current ADA Standards for floor or ground surfaces of clear floor or ground space.
-
4.5.4 Gratings
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
4.5.4 GRATINGS
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
3. Measuring Door Openings
Measuring Door Openings Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Overlap: ADA Standard Section 603.2.2
Section 603.2.2 covers the current ADA Standards for overlapping clear floor space at fixtures and turning spaces in toilet and bathing rooms.
-
Opening Force [§404.2.9]
Opening Force [§404.2.9] The maximum 5 lbf opening force applies to all accessible doors and gates except: fire doors (minimum opening force allowed by code) exterior...