Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
Search Results "Beveled"
Commonly Searched Documents
-
11B-504.5 Nosings
-
11B-504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
§ 38.83(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
§ 38.125(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
§ 38.159(c)(3) Ramp threshold
Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2....
-
§ 38.95(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
Priority 1: Approach & Entrance
Word Fillable Form (1.5MB) Word Non-Fillable Form (1.3MB) PDF Non-Fillable Form (0.8MB)
-
R408.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
1) Where the Standard specifically refers to 303
specifically refers to 303, such as 403.4 changes in level for walking surfaces: Here it is clear that changes in level that comply with either the ¼" maximum vertical rise, the ½" maximum beveled...
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
4.5.2 Changes in Level
Changes in level between 1/4 in and 1/2 in (6 mm and 13 mm) shall be beveled with a slope no greater than 1:2 (see Fig. 7(d))....
-
4.5.2 CHANGES IN LEVEL
Changes in level between 1/4 in and 1/2 in (6 mm and 13 mm) shall be beveled with a slope no greater than 1:2 (see Fig. 7(d))....
-
§ 38.23(b)(8) Platform entrance ramp
Thresholds between 1/4 inch and 1/2 inch high shall be beveled with a slope no greater than 1:2....
-
§ 38.125(b)(8) Platform entrance ramp
Thresholds between 1/4 inch and 1/2 inch high shall be beveled with a slope no greater than 1:2....
-
§ 38.83(b)(8) Platform entrance ramp
Thresholds between 1/4 inch and 1/2 inch high shall be beveled with a slope no greater than 1:2....
-
§ 38.95(b)(8) Platform entrance ramp
Thresholds between 1/4 inch and 1/2 inch high shall be beveled with a slope no greater than 1:2....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
at least 60 inches by 60 inches when the ramp changes direction; with no level changes in excess of ½ inch vertically and no level changes greater than ¼ inch vertically unless they are beveled...
-
608.7 Thresholds
In transfer type shower compartments, thresholds ½ inch (13 mm) high maximum shall be beveled, rounded, or vertical....
-
608.7 Thresholds
In transfer type shower compartments, thresholds ½ inch (13 mm) high maximum shall be beveled, rounded, or vertical....
-
11B-608.7 Thresholds
In transfer type shower compartments, thresholds ½ inch (12.7 mm) high maximum shall be beveled, rounded, or vertical....
-
608.7 Thresholds
In transfer type shower compartments, thresholds 1/2 inch (13 mm) high maximum shall be beveled, rounded, or vertical....
-
§ 38.159(b)(8) Platform entrance ramp
Thresholds between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) high shall be beveled with a slope no greater than 1:2....