Title II of the ADA applies to state and local government facilities, and the ABA requires that buildings or facilities that were designed, built, or altered with federal dollars or leased...
Search Results "Built-In Seating"
-
1. Public Rights-of-Way
-
1. Public Rights-of-Way
Title II of the ADA applies to state and local government facilities, and the ABA requires that buildings or facilities that were designed, built, or altered with federal dollars or leased...
-
11B-206.2.8 Employee work areas
The Department of Justice ADA regulations provide additional guidance regarding the relationship between these requirements and elements that are not part of the built environment....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
Flush Controls on Toilets
If plumbing valves are located directly behind the toilet seat, flush valves and related plumbing can cause injury or imbalance when a person leans back against them....
-
E2-3. Interior Stairs
If provided, are the interior stairs along these routes built so that people who are blind or visually impaired cannot hit their heads on the underside (i.e., protected with a cane-detectable...
-
MEASUREMENT TECHNIQUE
is measured between the perineal cutout and the hinge point at the back of the seat....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
§ 35.138(g) Ticket prices
The price of tickets for accessible seating shall not be set higher than for tickets to seating located in the same seating section for the same event. ...
-
Ground Floor
A building or facility always has at least one ground floor and may have more than one ground floor as where a split level entrance has been provided or where a building is built into a...
-
WORK AREA EQUIPMENT
As used in this document, this term shall apply only to equipment that is permanently installed or built-in in employee work areas....
-
WORK AREA EQUIPMENT
As used in this document, this term shall apply only to equipment that is permanently installed or built-in in employee work areas....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
II-5.2000 Methods for providing program accessibility.
ILLUSTRATION 4: A municipal performing arts center provides seating at two prices -- inexpensive balcony seats and more expensive orchestra seats....
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
accessible route between stories, an accessible route shall not be required to a mezzanine dining area where the mezzanine contains less than 25 percent of the total combined area for seating...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
accessible route between stories, an accessible route shall not be required to a mezzanine dining area where the mezzanine contains less than 25 percent of the total combined area for seating...
-
Sec.36.607(a)(2)
For example, if certain equipment is not covered by the code, the determination of equivalency cannot be used as evidence with respect to the question of whether equipment in a building built...
-
New Construction and Alterations
New Construction and Alterations Businesses whose facilities were built or altered since the ADA went into effect must comply with the ADA Standards for Accessible Design so that the...
-
10. Vertical Clearance at Exterior Stairs
10. ...are all exterior stairs built so blind persons and persons with low vision will not hit their head(s) on the underside (i.e.: protected with a cane detectable warning, such as the...
-
M14
Is the operating control (switch, lever, button, or pull) for each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor space for a parallel...
-
4.15.5(2)
(2) Free-standing or built-in units not having a clear space under them shall have a clear floor space at least 30 in by 48 in (760 mm by 1220 mm) that allows a person in a wheelchair to...