On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
Search Results "Wheelchair Space"
-
1009.2.3 Clear Deck Space
- Magnuson Group SMOKE Waste & Ash Receptacle
-
Size: ADA Standard Section 604.3.1
Section 604.3.1 covers the current ADA Standards for the size of the water closet clearance.
-
Clearance: ADA Standard Section 604.3
Section 604.3 covers the current ADA Standards for clearances around water closets and in toilet compartments.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3.
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....
-
F245.2.5.2 Parking Spaces
Where provided, at least one parking space shall comply with 1012.3, 1012.4, and 1012.5....
-
602.2 Clear Floor Space
602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
§ 36.302(f)(2) Identification of available accessible seating
(2) Identification of available accessible seating. A public accommodation that sells or distributes tickets for a single event or series of events shall, upon inquiry—
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Circulation Paths Serving Exempted Spaces [§203]
Circulation Paths Serving Exempted Spaces [§203] Portions of common use circulation paths serving exempt spaces within a work area are not required to comply, including routes to...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
1134A.4 Sufficient maneuvering space
Bathing and toilet facilities required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the...
-
603.2.1 Turning Space
603.2.1 Turning Space. Turning space complying with 304 shall be provided within the room....
-
Water Closet Clear Floor Space in Toilet Compartments
Other criteria for toilet rooms, including turning space, maneuvering space at doors, and clearances at other fixtures, typically results in additional clearance at water closets not in...
-
612.3 Turning Space
612.3 Turning Space. A turning space complying with 304 shall be provided within saunas and steam rooms....
-
11B-605.5.2 Maneuvering clearance
A minimum 66 inches (1676 mm) wide and 66 inches (1676 mm) deep maneuvering space shall be provided in front of the urinal....
-
11B-605.5.2 Maneuvering clearance
A minimum 66 inches (1676 mm) wide and 66 inches (1676 mm) deep maneuvering space shall be provided in front of the urinal....
-
1016.8.4 Turning Space
This section requires a turning space complying with 304.2.3 of the Architectural Barriers Act Accessibility Guidelines where resting intervals are provided adjacent to an outdoor recreation...
-
703.2.7 Character Spacing
703.2.7 Character Spacing. Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
304.3.2 T-Shaped Space
The turning space shall be a T-shaped space within a 60 inch (1525 mm) square minimum with arms and base 36 inches (915 mm) wide minimum....