408.3.2.2 Duration. Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
Search Results "Common Use Area"
Commonly Searched Documents
-
408.3.2.2 Duration
-
408.4.6 Car Controls
408.4.6 Car Controls. Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall.
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm)...
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1.
-
CORADA WORKSPACE
[See subsections ...]
-
FAQ: How do I upgrade my subscription?
You may change your subscription level at any time in your User Account! Upgrading to a Premium or Accessibility Specialist level subscription will provide access to more Corada...
-
§1630.16(c) Drug testing
(c) Drug testing—
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-604.9.1 Location
11B-604.9.1 Location. The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 12 inches (305 mm) minimum...
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.2.2 Hall signals
Hall signals shall comply with Section 11B-407.2.2.
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm)...
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall.
-
Temporary Suspension
Temporary Suspension In response to business and user concerns about the need for the detectable warnings specified in 4.29 at curb ramps and hazardous vehicular areas, the Access Board...
-
Implementation Alternatives
date of the final rule: (1) Require ten percent of future kiosks ordered to include accessible features or, in the alternative, (2) require one accessible kiosk per passenger check in area...
-
Kompan, Inc. FRE3013 - CometTail 60 Bench
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Kompan, Inc. KPL202 - Simplicity Bench
Requires the Premium User plan or above. (Login or upgrade your account!)
-
1009.4 Elevators
The elevator shall be accessed from an area of refuge complying with Section 1009.6....