[ECTCR UFAS 7.2] EXCEPTION: In alterations, when the provision of a counter complying with 904.4 would result in a reduction of the number of existing counters at work stations or a reduction...
Search Results "Altered Elevator"
-
904.4 Sales and Service Counters
-
904.4 Sales and Service Counters
EXCEPTION: In alterations, when the provision of a counter complying with 904.4 would result in a reduction of the number of existing counters at work stations or a reduction of the number...
-
11B-904.4 Sales and service counters
Exception: In alterations, when the provision of a counter complying with Section 11B-904.4 would result in a reduction of the number of existing counters at work stations or a reduction...
-
201.1 Scope
All areas of newly designed and newly constructed buildings and facilities and altered portions of existing buildings and facilities shall comply with these requirements....
-
Compliance date. (Section-by-Section Analysis)
New construction under title II and alterations under either title II or title III had to comply with the design standards on that date. See 42 U.S.C. 12183(a)(1)....
-
1007.6 Areas of refuge
Every required area of refuge shall have direct access to an enclosed stairway complying with Sections 1007.3 and 1019.1 or an elevator complying with Section 1007.4....
-
Section 35.151(c) Accessibility standards for new construction and alterations (Section-by-Section Analysis)
Section 35.151(c) Accessibility standards for new construction and alterations (Section-by-Section Analysis) Section 35.151(c) of the NPRM proposed to adopt ADA Chapter 1, ADA Chapter...
-
§ 35.151(c) Accessibility standards
(c) Accessibility standards.
-
ADA & Level Boarding - Perfromance [sic] Standards on Station-by-Station Basis
49 CFR §37.42(d)(2) DECEMBER 14, 2011
-
§35.151(a)
(a) Design and construction. Each facility or part of a facility constructed by, on behalf of, or for the use of a public entity shall be designed and constructed in such manner that...
-
§40.3(b)
(b) The standards prescribed in §40.4 are not applicable to:
-
4.1.6(4)(d)
(d) Doors. (i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch...
-
Stairs
Full handrail extensions at stairs are not required where they would project hazardously into circulation paths (§505.10, Ex. 3).
-
§ 37.43(e)(2)
(2) Costs that may be counted as expenditures required to provide an accessible path of travel include:
-
§ 37.43(e)(2)(iv)
(iv) Costs associated with relocating an inaccessible drinking fountain.
-
§ 35.151(c) Accessibility standards and compliance date.
(c) Accessibility standards and compliance date.
-
§ 37.9(c)
(c)
-
F218.2 New and Altered Fixed Guideway Stations
New and altered stations in rapid rail, light rail, commuter rail, intercity rail, high speed rail, and other fixed guideway systems shall comply with 810.5 through 810.10....
-
218.2 New and Altered Fixed Guideway Stations
New and altered stations in rapid rail, light rail, commuter rail, intercity rail, high speed rail, and other fixed guideway systems shall comply with 810.5 through 810.10....
-
Platform to Hoistway Clearance: ADA Standard Section 408.4.3
Section 408.4.3 covers the ADA Standards for the required clearance between the car platform and the hoistway landing of limited-use/application elevators.
-
Emergency Communications: ADA Standard Section 408.4.8
Section 408.4.8 covers the current ADA Standards for emergency communication systems in limited-use/limited-application elevators.
-
Play Components: ADA Standard Section 240.2
Section 240.2 covers scoping requirements in the current ADA Standards for play components.
-
11B-408.4.3 Platform to hoistway clearance
The platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.