Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
Search Results "Ramp Surface"
-
405.7.1 Slope
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
405.7.1 Slope. Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
R304.5.5 Clear Space
R304.5.5 Clear Space. Beyond the bottom grade break, a clear space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided within the width of the pedestrian street...
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings.
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
1009.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1012....
-
1009.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1012....
-
1013.4 Height
Tent platforms shall be 19 inches (485 mm) high maximum measured from the clear ground space to the tent platform surface....
-
1013.4 Height
Tent platforms shall be 19 inches (485 mm) high maximum measured from the clear ground space to the tent platform surface....
-
1.1.3 Walk running slope
primary direction of travel) by determining elevations at the ends of the walk, noticeable changes in slope, or at a maximum of 20 ft (6 m) intervals beginning at one end of the walking surface...
-
MITA Advisory Committee Members
MITA Advisory Committee Members MINORITY REPORT ON TRANSFER SURFACE HEIGHT RECOMMENDATIONS OF THE U.S. ACCESS BOARD ADVISORY COMMITTEE RE: NPRM: M301.2.1 AND M302.2.1 HEIGHT...
-
1.3 Previous Research
were more difficult to detect than steeper ramps....
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
-
4.26.4 Eliminating Hazards
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
4.26.4 ELIMINATING HAZARDS
A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
-
§ 38.95(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
- Choosing Level Size
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302 Description: The transfer surface size standard has two components: width and depth....
-
1017.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....